Bryant® Air Conditioners with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. The 113A has been designed utilizing Bryant’s Puron® refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy Star® guidelines.) for the most up-to-date ratings information.FEATURES / BENEFITSEfficiency13.0 - 13.2 SEER/10.8 - 11.0 EER (based on tested combinations)Microtube Technology™ refrigeration systemIndoor air quality accessories availableSoundSound level as low as 75 dBASound level as low as 74 dBA with accessory sound blanketComfortSystem supports Thermidistat™ or standard thermostat controlsReliabilityPuron® refrigerant - environmentally sound, won’t deplete the ozone layer and low lifetime service cost.

Scroll compressorInternal pressure relief valveInternal thermal overloadFilter drierBalanced refrigeration system for maximum reliabilityDurabilityDuraGuard™ protection package:Solid, durable sheet metal constructionDense wire coil guard available (3-phase units come standard with dense wire coil guard)Baked-on, complete outer coverage, powder paintApplicationsLong-line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.)Low ambient (down to -20°F/-28.9°C) with accessory kit Condenser Motor HP1/10 HP Maximum Piping Length250 ft Number of Fan Blades1 The DP14CH packaged home air conditioner is designed for horizontal installation. It comes with an energy-efficient scroll compressor that delivers dependable cooling for lower energy bills compared to lower SEER units. Plus, you will be happy to know that your Daikin system uses chlorine-free R-410A refrigerant.

Our packaged air conditioner units are also furnished with a variable-speed ECM blower motor that offers silent system startup and shutdown with extremely efficient performance. The heavy-gauge galvanized steel enclosure with powder-coat finish will shield your system from extreme weather conditions. Energy-efficient scroll compressor provides reliability and long life. Refrigeration-grade premium copper tubing and aluminum fin condenser coil configuration delivers outstanding heat transfer properties with R-410A refrigerant Self-contained packaged unit designed for horizontal installation
how much does a 4 ton central ac unit costUse our Comfort System Calculator Spec Sheets PDF Consumer Product PDFBefore purchasing this appliance, read important information about its estimated annual energy consumption, yearly operating cost, or energy efficiency rating that is available from your retailer.
how long does it take to thaw an ac unit

Online registration not required in California or Quebec.To view the full warranty certificate for this product click the link below. Triangle Inverter Split AC with Digital Inverter Compressor 2.0 TR 10 year warranty on Digital Inverter Compressor Cools You Fast Then Cools You Comfortably Save Energy Even When Alone Easy to Take Out and Clean 1,065 x 301 x 294 880 x 648 x 310Looking for rebates on a new air conditioner?
ac unit cleaning spray It's a click away. There are many perks of choosing an air conditioning unit that goes above and beyond in terms of efficiency and home comfort additions and home comfort additions - including rebates. Find an air conditioner that qualifies for a manufacturer rebate Looking for a high-efficiency air conditioner for your home? Not only can a budget-friendly, high-efficiency air conditioner provide great cooling capabilities, it can help you save money on your utility bills as well.

Find a high-efficiency air conditioner Find an extra-high efficiency air conditioner Just look for the ENERGY STAR label. Central air conditioners that are ENERGY STAR certified meet or exceed Department of Energy Standards for high-efficiency equipment. Find an ENERGY STAR certified air conditioner Need help selecting an air conditioner?Try checking out Frigidaire's air conditioner selection wizard. You can easily narrow-down your air conditioning system options - indoor component and IAQ included! Find your ideal air conditionerThe sun is back again with its ever increasing heat. The temperature all set to hit a new record this season, yet again. This is the probably the time when air conditioner industry is at its peak and most people look out for buying the best equipment in the market which suits their budget and comfort. Hence, we at Bijli Bachao, thought of providing some information which enables people to make an informed decision before buying an air conditioner.

The basic question: What size or tonnage should be chosen? When we say that we require 1 ton or 1.5 ton air conditioner, does that imply that we are talking about its weight? Here, ‘ton’ refers to the amount of heat removed by the air conditioner in one hour. The amount of heat removed is measured in British Thermal Units (BTU). Hence, higher the BTU, greater will be the cooling capacity, which means the AC will be able to cool a larger area. 2 ton= 24,000 BTU/hr and so on. Historically a ton was referred to as a space that can be cooled using 1 ton of ice. And that is how the term originated. Now that we know what the term ‘ton’ implies, our next step would be to choose the right ton air conditioner. Frankly, there is no universal answer to this question. The tonnage depends on several factors like room size, city of use, number of people in room, number of appliances in room, etc (more in our article: Things that impact electricity consumption in air conditioners).

Also the tonnage not only depends on the factors listed earlier, but also on the season. In peak summers when there is more heat, more tonnage is required to cool a room, whereas in the month of March, it is lesser (more in our article: Electricity Bills vary with seasons and how Inverter Technology can help). Even between day and night the tonnage requirement varies as more tonnage is required during the day (as heat is more) and less tonnage is required during the night (as heat is less). However, whenever we choose the tonnage, we have to keep the peak summer day in mind and choose accordingly. Our article on ‘Split vs Window’ air conditioner elaborates more on the factors affecting AC size selection. Buyers should make sure that they select optimum size of air conditioners. This is because undersized air conditioner cannot cool properly and oversized AC consumes more electricity (to know the reason read: Power Saver Devices for Air Conditioners). And a fixed speed air conditioner if sized for the peak summer day will be oversized during most other times (in comparison Inverter Technology air conditioners automatically adjust their tonnage as per room’s requirement at any point, read more at: Air Conditioners with Inverter technology can help save electricity).

Although a lot of manufacturers have online calculators to calculate tonnage but we prefer using the one from Sharp Air Conditioners. Below are the links: Fixed Speed AC tonnage calculator: http://sharpproducts.in/dsupport/60.zip Inverter AC tonnage calculator: http://sharpproducts.in/dsupport/52.zip The reason we prefer these calculators is that they show more detailed tonnage requirement for the room. Most others round up the number resulting in oversizing (for e.g. many other calculators will round up 1.2 ton to 1.5 ton whereas there are many brands that do make ACs of 1.2 tons and it is better to go for 1.2 ton AC than 1.5 ton in order to avoid oversizing). Also please note that if you buy a BEE 5 star rated 1.5 ton AC for a room that needs 1.2 tons of cooling, it will be as good as buying a BEE 3 star 1.2 ton AC (oversizing causes inefficiency which will result in extra electricity usage). After size, comes the efficiency The next and a very important differentiating factor between air conditioners is the efficiency.

Efficiency in basic terms is defined as output/input. Efficiency of air conditioners is usually given by the following terms: 1.Energy Efficiency Ratio or EER. EER = Amount of heat removed per hour/ power consumed. Thus, higher the amount of heat removed per hour per unit of power consumed, higher is the efficiency of air conditioner. Also, higher the EER, better is the airUsually, EER of an air conditioner is measured under a specific condition (35 degree C, outdoor temperature; 27 degree C indoor temperature and 50% relative humidity). 2. Co-efficient of Performance or COP Before defining COP, consider the conversion from BTU to kW hr(kilowatt hour). 1kW hr = 3412 BTU 1kW = 3412 BTU/hr or 1W = 3.412 BTU/hr The above relation gives the amount of heat removed in ‘W’. Now, COP of air conditioner is given by COP = amount of heat removed in W/ power consumed in W Thus, COP is a unit less quantity. Thus, just like EER, higher the COP, better is the air conditioner.

The following relation establishes the relation between EER and COP EER = 3.412 * COP Show efficiency and be a ‘star’ performer Whenever we go to buy a new air conditioner, we find a label on the same. the most important factor apart from the cost, which determines the selection of an air conditioner. Bureau of Energy Efficiency (BEE) mandates every air conditioner to have this label. A representation of the same is given below: Higher the number of stars, greater will be the efficiency or EER. One important thing to be noted here is that EER is given by W/W (which is also the same as COP) whereas we have defined EER by BTU/hr/W. EER in BTU/hr/W = 3.413 * EER in W/W BEE has revises the start rating of air conditioners from time to time. Hence, a 5 star AC in the previous year may become a 3 star AC the next year after revision of rating takes place. You may recognize the validity of the label from the ‘label period’ section printed on the label.

Below you will find the current star rating (w.e.f. 1st January 2014). As you can see that each star rating is a range of EER. So it is possible that as AC with EER of 3.29 is rated as BEE 3 star and another of 3.3 is rated as BEE 4 star. It is also possible that AC with EER 3.1 is BEE 3 star and another of 3.49 is BEE 4 star. Thus it is very important that while looking at BEE star rating, you also look at the EER of the AC. If we take the numbers above, we can see that with increase of every star rating there is a possibility of saving up to 14%. So a BEE 5 star rated AC can be up to 35% or more efficient than a BEE 1 star AC and 15-20% more efficient than BEE 3 star AC. The ratings above are based on savings in machinery. In comparison an Inverter tech AC being flexible tonnage AC can save more over BEE 5 star AC. The reason being it not just saves on using efficient machinery but also on flexible tonnage. So the savings can be at least 15-20% more over BEE 5 star rated AC because of savings in changing heat load between seasons and days and nights, and additional saving can be achieved because when you buy a fixed speed AC you oversize even for the peak summer day.

And that is why some manufacturers claim up to 60% savings on inverter tech AC (although achieving 60% will depend on how you size the AC). It is true that everything comes with a cost. A 5 star air conditioner will definitely be costlier than a 1 star air conditioner of the same company. And Inverter technology AC costs further more. However, it is also true that the same 5 star air conditioner is much more efficient than a 1 star air conditioner. Hence, a 5 star air conditioner will provide the same amount of cooling using lesser power than a 1 star air conditioner of same tonnage. This leads to savings in operating cost. You may recover the incremental capital cost used to purchase a higher star rated air conditioner in a matter of few years. We typically recommend going for a BEE 5 star rated AC or further Inverter Tech AC if usage of AC is more than 1000 hours in a year and per unit cost of electricity is more than Rs 5 per unit (if the per unit cost is higher, it is recommended for lower the yearly usage also).

1. Kindly ensure that you select the right tonnage of air conditioners. Oversizing or under sizing may either burn your pockets or may not provide you the right comfort level. 2. Ensure that the new air conditioners have the revised star rating labels. (Refer ‘label period’ section on the label). 3. Kindly note that the EER rating on the label is given in W/W. Whereas sometimes on the internet you will find EER rating given in BTU/hr/W. (we have given the relation between the two above.) 4. Although ‘more stars, more cost’ is true, ‘more stars, more savings’ is also true. After all, when it comes to efficiency, ‘operating cost matters more than capital cost’. Select your city, dimensions of room, usage hours and sunlight checkboxes to get our recommendations. The inputs are on the left size and our recommendations on the right side. Also please note that these calculations are for a regular room in a house. If the room size is more than 400 sq ft then it would be better to call an engineer to do the evaluation.