I've been experimenting with my family lately. Or is it, experimenting on my family? In either case, I've got the data to confirm something I wrote in a 2011 article. But before I tell you what I did, first let me show you what happened. Here is Exhibit A: A Moisture Mystery. What do you think happened to cause the humidity (blue data) in the air in our condo to rise like that? Why did the humidity spike? The graph above shows the temperature and dew point, measured with a data logger on the main return grille in the living room, from early August to early September. The indoor temperature in our condo stayed mostly around 75° F, with a few excursions when we adjusted the thermostat. But the humidity showed something really interesting. Starting on 18 August and ending on the 23rd, the dew point took a significant jump upwards. It had been averaging about 60° F then shot up to about 65° F for a few days before coming down. Here are a few hypotheses: I finally started showering and then got freaked out and stopped.
I showered without using the bath fan. I brought in a lot of outdoor air for ventilation. Well, it was none of the above. The answer is given in the two graphs below. This thermostat setting is to blame At about 8 am on 18 August, I changed the thermostat fan setting from "auto" to "on" and ran it that way for the next five days. As you can see in the graph above, the relative humidity (RH) also spiked and averaged 70% during the time the fan was running continuously. Why did the RH and dew point go up? While the air conditioning cycle was running, the indoor coil got cold. Water vapor from the air passing over it would condense on the coil. When the compressor turned off, the coil would warm up. The water remaining on the coil normally would just sit there until the next cycle, with some of it evaporating and sitting in the air inside the coil housing. But with the fan running continuously, the air passing over the coil as it warmed up would evaporate that water and put it right back into the house.
Keeping the relative humidity at 70% is not a good thing. ac power supply l nThat's about the threshold where mold can really take off. new ac compressor or new unitIf we left our thermostat set to the fan-on position all summer, I'm sure we'd have a mold factory in our condo. 3 ton gas heating and air conditioning systemsSo if you've been told to run the fan continuously by someone who sold you an electrostatic filter, UV lights, or some other indoor air quality device, you may not have been given the complete story on how such products affect the IAQ in your home. The higher relative humidity also meant that our home was less comfortable. We average about 58-59% with the fan set to auto, and even that's not ideal. The main reason for that is the short runtimes of our air conditioner, which I wrote about last week.
The graph above shows the dew point data by themselves with the mean values before, during, and after the fan-on period. One thing that surprised me was how quickly the humidity rose when I changed the thermostat. Within minutes, I noticed the RH reading moving up. But getting back to RH levels below 60% took a couple of days after I switched it back to the "auto" position. Why you shouldn't leave your thermostat set to the fan-on position I described the reasons not to set your thermostat to the fan-on position in my previous article, but I'll restate them here: If you're in a humid climate, you may push the air in your home into the mold-growing range of relative humidity, especially if your air conditioner is oversized. Your energy bills will be higher. You'll increase your total duct leakage because the fan will be running all the time. If you have unbalanced duct leakage, you may also increase the air leakage across your building enclosure.Do the experiment yourself.
Don't Set Your Air Conditioner Thermostat Like This My Big Fat Oversized Air Conditioner The Sucking and the Blowing — A Lesson in Duct Leakage 4 Ways a Bad Duct System Can Lead to Poor Indoor Air QualityHonda Odyssey Blower Motors Replacement PLEASE SELECT Your Honda Odyssey Year PLEASE SELECT Your Honda Odyssey Side PLEASE SELECT Your Honda Odyssey Side Parts 2005 - 2010 Honda Odyssey Heater Blower Motor & Fan Assembly - Front Side 1999 - 2004 Honda Odyssey Heater Blower Motor & Fan Assembly - Front Side 1999 - 2004 Honda Odyssey Heater Blower Motor & Fan Assembly - Rear Side 1995 - 1998 Honda Odyssey Heater Blower Motor & Fan Assembly Most Orders Shipped Priority Mail Distribution Centers in NJ, GA, NV Norton Verified & Secure What Go-Parts Guarantees You: Every part comes with a limited lifetime warranty. We carry only the highest-quality brands in the industry, including TYC, KOYO, DEPO, and Modine, just to name a few.
All parts meet OEM quality standards, and in most cases exceed the quality of the original product. We offer a no-questions 100% money back guarantee on all items returned within 30 days of delivery. If you receive an incorrect item from us, we will immediately pay for return shipment and send you the correct item. (For items over $100 we will ship the new item after receiving the original, which we will pay for). Item in Good Condition Guaranteed If the part we ship to you arrives in damaged or non-working condition, we will ship another item out to you immediately. (For items over $100 we will ship the new item after receiving the original, which we will pay for.) Most orders are shipped out the same day as they're received. Our prices are hands-down some of the lowest you'll find on the net. If you find a product sold for a lower price by another vendor, we will beat or match their price. was a real pleasure to buy my automobile parts from. Their website is very user friendly, accurate, excellent price, and simple to place an order.