fan coil unit purpose

Sei in: Home > Services > Fan-coil units 2 and 4 pipes (non ducted) Ducted 2 and 4 pipes Liquid chilling packages and heat pump units A “fan-coil unit” is a factory made assembly which provides the functions of cooling and/or heating air using chilled or hot water with air flow to the room ensured by one or more electrically driven fans. Fan Coil Units may be of the cabinet style, within a room, for free air delivery, or of the chassis style, concealed within the building structure with minimal ducting appropriately connected to the inlet and/or outlet of the unit. The principal components are: one or more heat exchangers, one or more fans with electric motors, condensed water collecting facilities when cooling.As the leader in hydronic fan coils, IEC offers the largest selection of products in the industry. Our offering covers the full spectrum of horizontal and vertical systems, modular hi-rise, and belt-driven fan coils, as well as innovative designs created specifically for hotel rooms, hospital rooms, dormitories, apartments, and condominiums.

Our ongoing commitment to research and development means that we are bringing you the best products available, such as our innovative RestoraMod, which cuts replacement time for hotel room fan coils by over half. In addition, IEC offers unique products with energy saving technology such as our ECM motors, and features such as foil face and closed cell insulation for an even higher level of IEQ (Indoor Environmental Quality). > Comfort units / Fan coil units > Air handling units > Autonomous (Self-contained air conditioning units) > Swimming pool deshumidification > Precision air conditioning > Ventilation & extraction fans > Domestic water solutions // terms and conditions of sale > System control and supervision > COADIS LINE 600 > COADIS LINE 900 > Without control / RTR - E > FRESH AIR CONTROL > Valves and servomotors > Easy Smart CIATControl CIAT launches its newest range of AHU CLIMACIAT™ The CIAT geothermal product range evolves

SF units are supplied as fans and water coils in one casing. Hot or cold water is supplied to the SF unit where it passes through the coil that either heats or cools the air which is then put back into the room.
2 ton ac unit installed Powder coated finish through a special bonding process provides an attractive finish in a variety of colors.
central ac unit line frozen Exclusive Condensate Removeal System (CRS) eliminates standing water, reducing odors and humidity.
york water cooled ac units Multiple choices of insulation are also available to further improve IAQ. Removable panels and accessible end pockets provide easy access, saving time and money during installation and maintenance. Resilient motor mounts and insulated discharge panels reduce noise and improve occupant comfort.

Extended end pockets and reversible coils add flexibility to installation and maintainability.Air Side Fan Coils Water Side Fan Coils The Highline 270 EC horizontally mounted fan coil range is 270mm deep and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.16 – 0.34W/l/s; fitted as standard with our ECO wire mesh filter; with inlet and discharge attenuator options available. The versatile design allows it to be mounted in either ceiling or floor void applications. Highline 270 EC - all specification documents: GA: Highline 270 EC/DC (pdf) GA: Highline 270 EC/DC DXF (dxf) GA: Highline 270 EC/DC DWG (acad)IOM MANUAL ISSUE H (pdf) Highline 170 EC (Slimline) The Highline 170 EC horizontally mounted fan coil range is 170mm deep and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.19 – 0.43W/l/s; Highline 170 EC (Slimline) - all specification documents:OM Manual - Slim Water (msword)GA - Slimline Waterside (pdf)WD - Slimline Waterside (pdf)Selection Data - Slim Water (msword)

HighLine 170 EC (Slimline) The Highline 170 EC horizontally mounted fan coil range is 170mm deep and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.21 – 0.47W/l/s; This range is available as cooling only, or cooling with electric heating. HighLine 170 EC (Slimline) - all specification documents:O&M Manual Slim Air (msword)GA: Slimline Airside (pdf)Selection Data - Slim Air (pdf) The Lowline 220 EC vertically mounted fan coil range is 220mm deep as chassis only, and 235mm deep when fitted with a case option, and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.10 – 0.16W/l/s; fitted as standard with our ECO wire mesh filter. Lowline EC - all specification documents:Lowline Technical Specification (msword)GA: Lowline Waterside (pdf)O&M Manual - Lowline (msword)WD: Lowline Waterside (pdf) The Highwall 200 EC vertically mounted fan coil range is 200mm deep and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.16 – 0.50W/l/s;

Complete with built-in discharge and inlet attenuation, providing high performance selections down to NR25, lending itself to application in the residential market for installation behind wardrobes and in concealed installations. The Highwall 260 EC vertically mounted fan coil range is 260mm deep and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.14 – 0.43W/l/s; Complete with built-in discharge and inlet attenuation, providing high performance selections down to NR20, lending itself to application in the residential market for installation behind wardrobes and in concealed installations. The Highline 260 EC horizontally mounted fan coil range is 260mm deep and fitted with high efficiency EC/DC motors, offering specific fan powers (SFP) between 0.20 – 0.35W/l/s; Highline 260 EC - all specification documents:OM Manual - High 260i Air (msword)GA - Highline 260i Airside (pdf)WD - Highline 260i Airside (pdf)American Aldes IQ-VFC is an intelligent ERV-integrated vertical fan coil for high-rise apartments, condominiums, and hotels.

The IQ-VFC takes all the benefits of a standard vertical fan coil and builds in the energy-efficient ventilation of an Energy Recovery Ventilator (ERV). The result is a heating, cooiling, and ventilation solution that works smarter, saves space, and reduces costs. Highly Efficient EC Blower Motor Water-to-Air Coil for Heating and Cooling Positive Protect™ senses the temperature near the water-bearing components, and when it is 38°F or lower, it creates a safe mode that turns off both ERV blowers, closes the fresh air inlet damper, and opens the hot water actuator to prevent freezing conditions. Integral ERV airflow balancing features are built into every unit, enabling a trained installer to accurately balance incoming and outgoing air streams. The fan coils were independently sound tested to meet (NC) 35 criteria. The ERV is purpose-designed to reduce redundant metal components. The proprietary custom circuit board offers superior control of essential operating parameters.